Potassium sensor S-601 PET 190 μm

Foil sensor for potassium monitoring

The potassium sensor S-601 is a foil sensor with electrodes for electrochemical determination of potassium concentrations of samples. The accensors pH-sensor consists of two electrodes (a K+-sensitive and a non-sensitive Ag/AgCl reference electrode) on a transparent PET foil. The readings are taken by measuring the open circuit potential/voltage between both electrodes. Potential (E) and pH have a linear relationship (between the operating range of pH 1 μM and 0.1 M) so the potassium concentration of an unknown analyte can be calculated using the pre-determined slope and an offset E value (E0 determined by measuring the potential in a calibration solution of known K+ concentration). The reference electrode and overall sensor can be used in analytes with different chloride concentrations thanks to a solid-state electrolyte layer. Once used, the sensor must be kept hydrated for further application and not allowed to dry out.

The foil carrier is made of transparent PET material and the sensor is flexible, although care should be taken not bend the electrode spots. A connection between sensor and measurement electronics can be established via accensors connect or ZiF-connector. Contact pads are covered with an oxidation protection. The data given refers to the use of the sensor in combination with the ACO accensors D-301 measurement device and our accensors iOS application. The measuring output will display the measured potential (in mV) or if the sensor is calibrated (onepointsoftware calibration at 21°C or two-point at other temperature) output can be given as concentration K+.

Technical Data
Dimensions L x W x H in mm100,0 x 13,0 x 0,2
Measurement range1 μM and 0.1 M
Accuracy (in aqueous solutions)+/- 4 mV
Potential response (at 21 °C)58.2 mV per decade +/- 0.7
Set-up time (time till stable output)30 min
Response time (t90) <20 sec
Sensor drift8 mV in first 24 hrs then stable
Max Lifetime (in use)7 days
Lifetime (in storage)3 months
Storage temperature10°C – 20°C
Storage humidity35 % RH – 50 % RH
Measuring environment
Temperature18 °C – 25 °C
SamplesDiverse*

*must be sufficient moisture for contact to be maintained between both electrodes

Fig.1 Output potential for sensors measured in different buffer solutions (no. sensors = 5)

All mechanical dimensions are valid at 25 °C ambient temperature, if not differently indicated. All data except the mechanical dimensions only have information purposes and are not to be understood as assured characteristics. Technical changes without previous announcement as well as mistakes reserved. Load with extreme values during a longer period can affect the reliability. Typing errors and mistakes reserved. Product specifications are subject to change without notice.

Get in touch with us

Please enable JavaScript in your browser to complete this form.
Name

Email Address

info@accensors.com

Call Us

+49 (0)5772 200 934 0

Keep up to date

We will contact you at regular intervals

Get in touch with us

Please enable JavaScript in your browser to complete this form.
Name

Email Address

info@accensors.com

Call Us

+49 (0)5772 200 934 0

WordPress Cookie Notice by Real Cookie Banner